EVI Power 1KVA Online Rack Mount UPS System with Dual 9Ah Batteries 900W Backup Power Supply with SNMP Support
$ 90.94
MODEL: EP-UPS1000UC13OR Capacity (VA / Watts): 1,000 VA / 1,000 W Phase: Single phase with ground INPUT Nominal Voltage 200 / 208 / 220 / 230 / 240 Vac Operating Voltage Range Low voltage of transferring to bypass: 160 Vac ± 5 % @ 100 % – 80 % load, 120 Vac ± 5 % @ 70 % – 60 % load, 110 Vac ± 5 % @ 60 % – 50 % load (Ambient temp. < 35 °C) Low threshold voltage of recovering from bypass: 175 Vac ± 5 % @ 100 % – 80 % load, 135 Vac ± 5 % @ 70 % – 60 % load, 125 Vac ± 5 % @ 60 % – 50 % load (Ambient temp. < 35 °C) High voltage of transferring to bypass :300 Vac ± 5 % High threshold voltage of recovering from bypass: 290 Vac ± 5 % Input Voltage Range: 55 – 150 Vac or 110 – 300 Vac @ 60 % load, 80 – 145 Vac or 160 – 300 Vac @ 100 % load Operating frequency range: 40 – 70 Hz Power Factor: 0.99 Generator input: Supported OUTPUT Output Voltage: 200 / 208 / 220 / 230 / 240 Vac Power Factor: 1 Voltage regulation: ± 1 % Frequency Line mode (synchronized range): 47 – 53 Hz or 57 – 63 Hz Frequency Bat. mode: 50 / 60 Hz ±1 Hz Crest Factor 3:1 Harmonic Distortion (THDv): ≤ 2 % THD (Linear load) ≤ 4 % THD (Non-linear load) Waveform: Pure Sinewave Transfer time: AC mode <-> batt. mode -Zero Inverter <-> bypass- 4 ms (Typical) EFFICIENCY AC Mode: 88 % 92 % 92 % Battery mode: 85 % 88 % 90 % BATTERY Battery type: 12 V, 9 Ah Number of batteries: 2 Typical recharge time: 4 hours charge to 90 % capacity Charging voltage: 27.4 Vdc ± 1 % 54.7 Vdc ± 1 % 82.1 Vdc ± 1 % Charging current (max): 1 A or 2 A SYSTEM FEATURES AC mode: Ambient temp. < 35 °C – 105 % – 110 %: UPS will transfer to bypass mode within 10 min of return of utility power 110 % – 130 %: UPS will transfer to bypass mode within 1 min of return of utility power 130 % – 150 %: UPS will transfer to bypass mode within 5 sec of return of utility power > 150 %: UPS will transfer to bypass mode immediately upon return of utility power Battery mode: 35 °C < ambient temp. < 40 °C 105 % – 110 %: UPS will transfer to bypass mode within 1 min of return of utility power 110 % – 130 %: UPS will transfer to bypass mode within 5 sec of return of utility power > 130 %: UPS will transfer to bypass mode immediately upon return of utility power Short circuit: Hold whole system Overheat Line mode: Switch to bypass. Backup mode: UPS will shut down immediately Battery low: Alarm and switch off EPO (optional): Shut down UPS immediately Audible & visual alarms: Line failure, battery low, over load, system fault MANAGEMENT Communication ports: USB, RS232, SNMP card (optional), Relay card (optional) OPERATING ENVIRONMENT Operating temperature: 0 – 40 °C Storage temperature: -25 °C – 55 °C Humidity range: 20 – 90 % RH @ 0 – 40 °C (Non-condensing) Recommended altitude: < 1500 m Noise level: Less than 50 dBA at 1 m PHYSICAL FEATURES Dimensions (W * D * H): 440mm * 325 mm* 86.5 Approx. net weight (kg): 11.3